德國(guó)羅德與施瓦茨R&S NRP-ZKU USB接口電纜

型號(hào): NRP-ZKU

--- 產(chǎn)品參數(shù) ---

  • 單位 臺(tái)
  • 數(shù)量 10

--- 產(chǎn)品詳情 ---

德國(guó)羅德與施瓦茨R&S NRP-ZKU USB 接口電纜

 

型號(hào): NRP-ZKU

USB Leistungsmesskopfkabel(1,50m), Für NRPxxS/T/A/SN/TN/AN Messkopfbetrieb am Laptop/PC, Stromversorgung über USB, Stecker: M12(sensorseitig) - USB A (Zubeh?r)

Definitions  

Product data applies under the following conditions: 

?

   Three hours storage at the expected operating temperature followed by 30 minutes warm-up, unless otherwise stated 

?

   Specified  environment

al conditions met 

?

   Recommended calibration interval adhered to 

?

   All internal automatic adjustments performed, if applicable 

Specifications with limits 

Describe warranted product performance by means of a range of val

ues for the specified parameter. 

These specifications are mark

ed 

with limiting symbols such as , ±, 

or descriptions such as maximum and minimum. 

Specifications in normal print refer to par

ameters where compliance is ensured by the 

design or derived from the measurement of

related parameters. 

Specifications in 

bold

 print are 100 % tested. Test limits have been narrowed by guard bands to take into account measurement 

uncertainties, drift and aging, if applicable. 

Specifications without limits 

Describe warranted product performance by means of a representativ

e value for the specified param

eter. Limits are omitted whene

ver 

they are not relevant for the spec

ification (e.g. dimensional data). 

Typical values (typ.) 

Represent the population mean for the given 

parameter, derived from the design and/or 

production testing. Typical values are no

warranted by Rohde & Schwarz. 

Limits of uncertainty 

Expanded uncertainties with a coverage factor of 2, calculated fr

om the test assembly specifications and the modeled behavior o

f the 

sensor, including environmental c

onditions, aging, wear and tear, if applicable. T

he given values represent limits of uncertain

ty that are 

met by the Rohde & Schwarz instrument after calibration at a prod

uction or service site. Limits of

 uncertainty (in italics) are

 defined in 

EN 60359 and have been determined in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM). 